Rotary limit switches
• Rotary limit switches are used to control and measure movement of industrial machinery by reading the rotation angle and/or counting the number of revolutions of a shaft.
• They operate as an auxiliary controller for electric motors through a power interface.
• The switch shaft can be connected to a motor and after a preset number of revolutions the cams operate a switch.
• Each cam can be set with a high accuracy due to precision cam adjusting screws.
• Utilisation category: AC 15
• Rated operational voltage: 250 V
• Operational temperature -40°C/+80°C
• Rated current: 3A operational / 10A thermal
• Conformity to standards: EN 60204-1/35, 60947-1/5-1, 60529, CSA-C22.2 No 14-13, UL 508
Oscar series - Wormgear limit switches
• Can be equipped with up to two cam sets (up to 10 switches) with potentiometers (alone or on top of cam sets with up to 3 switches) and Yankee absolute encoders (on top of cam sets with up to 4 switches)